AEROTEST SIMULTAN

Mobile test system for breathing air and Nitrox applications up to 300 bar

The portable AEROTEST SIMULTAN test system enables reliable analysis of breathing air and Nitrox in accordance with DIN EN 12021, using detector tubes and an impactor.
  • Measures CO, CO₂, water vapor, and residual oil
  • Compact design for mobile use

Technical data

AEROTEST HP

Carrying caseLength × Width × Height (mm)350 × 300 × 85
ColorBlack
Weight with contentsCa. 3 kg
Pressure reducerInletExternal thread G5/8–300 bar (hand connection)
Max. inlet pressure300 bar
Pressure gauge0 - 400 bar
Outlet9 mm quick connector for measuring device
Overpressure valveSet to 10⁺² bar
Adapter 1InletInternal thread G5/8–200 bar
OutletInternal thread G5/8–300 bar for pressure reducer
Adapter 2InletInternal thread G5/8-200 bar
OutletInternal thread G5/8-300 bar for pressure reducer
Measuring deviceLength × Width (mm):100 × 38
Height including Dräger tube holder (mm):230
Connection for compressed air supply9 mm plug-in nipple
Inlet pressureFactory-set on delivery:8,5 bar
Volume flowCO and CO₂ tubes:0,2 l/min
Impactor and H₂O tubes:4 l/min

AEROTEST ALPHA

Carrying caseLength × Width × Height (mm)350 × 300 × 85
ColorBlack
Weight with contentsCa. 3 kg
Pressure reducerInletplug-in nipple
Max. inlet pressure15 bar
Pressure gauge0,3 - 15 bar
Outlet9 mm quick connector for measuring device
Overpressure valveWithout
Adapter 1Inlet9 mm quick connector
OutletExternal thread G 1/4
Adapter 2InletInternal thread G 1/4
Outletplug-in nipple 12 mm
Measuring deviceLength × Width (mm):100 × 38
Height including Dräger tube holder (mm):230
Connection for compressed air supply9 mm plug-in nipple
Inlet pressureFactory-set on delivery:3,0 bar
Volume flowCO and CO₂ tubes:0,2 l/min
Impactor and H₂O tubes:4 l/min
  • Details & Features

    The portable breathing air tester AEROTEST SIMULTAN HP enables reliable purity measurement of compressed air. Using detector tubes, CO, CO₂, and water vapor are measured simultaneously; an impactor detects mineral and synthetic oils. Incorrect results due to user error are virtually eliminated, and no calibration is required. A pressure reducer with special nozzles ensures constant flow rate and consistent measurement accuracy.

    The AEROTEST SIMULTAN HP checks compliance with DIN EN 12021, offering reliable protection for both health and equipment.

    Measurement principle

    To detect oil content, compressed air flows through 20 nozzles directly onto a glass impaction plate in the impactor. Due to their mass inertia, oil aerosols are deposited, filling the recesses of the glass surface and reducing light scattering – making even minimal oil quantities visible. The specific nozzle arrangement enables quantitative evaluation, regardless of the oil type. Vaporized oils are not detected under typical operating temperatures.

    To conduct the measurement, the AEROTEST SIMULTAN HP is connected to a compressor, cylinder, or pipeline. After at least three minutes of flushing (without the impactor), the measurement is performed at 4 l/min. The impactor is inserted first, followed by the detector tube. The measurement takes five minutes. The protective foil is then removed and the result is read.