G series: MINI-VERTICUS & VERTICUS – The turnkey compressors for helium, argon, neon and other noble gases

BAUER VERTICUS Super-Silent, sound-insulated, helium compressor, side view
BAUER VERTICUS Super-Silent, sound-insulated, helium compressor, side view
BAUER VERTICUS Super-Silent (sound-insulated) high-pressure compressor
BAUER VERTICUS Super-Silent (sound-insulated) high-pressure compressor
BAUER MINI-VERTICUS Super-Silent (sound-insulated) medium-pressure compressor
BAUER MINI-VERTICUS Super-Silent (sound-insulated) medium-pressure compressor
BAUER VERTICUS Super-Silent (sound-insulated) high-pressure compressor
BAUER VERTICUS Super-Silent (sound-insulated) high-pressure compressor
BAUER VERTICUS Super-Silent, sound-insulated, helium compressor, side view
BAUER VERTICUS Super-Silent, sound-insulated, helium compressor, side view
Compressor control B-CONTROL MICRO
Compressor control B-CONTROL MICRO

Now significantly quieter: thanks to the new anti-vibration frame and noise-optimised Super Silent housing

Compact dimensions: For installation wherever space is at a premium

Ergonomic design: optimum accessibility and operation

B-DRAIN: The new automatic condensate drain is quieter and saves energy

Very easy to maintain: The tension of the V-belt does not have to be adjusted

The new generation of stationary compressors from the VERTICUS series once again demonstrates BAUER’s leading-edge technological status.

Optimised for helium and other noble gases, MINI-VERTICUS and VERTICUS are the gas-tight and helium-tight classics in the successful BAUER G-series.

The new MINI-VERTICUS and VERTICUS combine the legendary BAUER compressor blocks with improved components and ultra-modern design! During the redesign, the focus was on ergonomics, making operation as easy as possible, reducing noise and boosting efficiency.

All control elements that are important for everyday operation are ergonomically arranged and easily accessible from the front.

The advanced B-CONTROL MICRO is more powerful and ready to communicate with the B-APP for remotely controlling and monitoring the compressor.

Recirculation of blowby and lost gas from the automatic condensate drain into the intake buffer combined with efficient encapsulation of the safety valves effectively minimises gas losses.

Low speeds and optimised grading of the compressors provide the basis for the very best compression ratios for the compression of noble gases.

All the information you need at your fingertips!

Display B-CONTROL MICRO
Display B-CONTROL MICRO

B-CONTROL MICRO compressor control
The B-CONTROL MICRO is a modern, easy-to-use compressor control with colour display for the control and reliable monitoring of all basic functions. Read more

MINI-VERTICUS and VERTICUS – the concept
MINI-VERTICUS and VERTICUS – the concept

MINI-VERTICUS and VERTICUS – the concept
Powerful compressor systems featuring compact design, small footprint and outstanding ease and convenience of use. Read more

Vertical unit concept, G series with intake buffer and condensate collecting vessel on common base frame
Vertical unit concept, G series with intake buffer and condensate collecting vessel on common base frame

Helium configuration
The G Series MINI-VERTICUS and VERTICUS are purpose-designed helium / gas compressors for industrial applications. They are especially modified for compression of helium and other rare gases. Read more

IK 120 II-G compressor block
IK 120 II-G compressor block

Compressor blocks
With their outstanding surface hardness, plasma-nitrided and plateau-honed cylinders are able to achieve extremely long service lives combined with low energy consumption and reliable oil lubrication of cylinder surfaces. Read more

B-DRAIN automatic condensate drain
B-DRAIN automatic condensate drain

B-DRAIN automatic condensate drain
The automatic condensate drain automatically removes the condensate that forms during compression (water/oil mixture) from the intermediate separators and the final separator and collects it in a condensate vessel. Read more

AIR COOLING
AIR COOLING

AIR COOLING
Compressors in the MINI-VERTICUS and VERTICUS series are cooled directly using ambient air. The heat they generate is discharged efficiently and effectively. Read more

Drive
Drive

Drive
A low-maintenance, self-tensioning V-belt drive is used for power transmission in the MINI-VERTICUS & VERTICUS series. The integration of a motor rocker means that the tension of the V-belt does not need to be adjusted. The compressor units are fitted ex works with energy-saving three-phase motors which meet the requirements of energy efficiency class IE3.

Super-Silent cladding
Super-Silent cladding

Super Silent version
Super Silent housing reduces the noise level of the compressor unit and enables an exhaust shaft to be used. For units in the MINI-VERTICUS & VERTICUS series, Super-Silent sound insulation can be retrofitted on request.

Vertical unit concept, G series with intake buffer and condensate collecting vessel on common base frame
Vertical unit concept, G series with intake buffer and condensate collecting vessel on common base frame

Complete version
Separate intake buffer and condensate vessel, completely piped and mounted on common base frame with compressor unit. Instead of combined intake buffer and condensate vessel without common base frame.

B-CONTROL II compressor control
B-CONTROL II compressor control

B-CONTROL II
The BAUER B-CONTROL II compressor control is the extended version of the B-CONTROL MICRO basic compressor control. Read more

Temperature Sensor
Temperature Sensor

Monitoring the intermediate pressures and intermediate stage temperatures
This monitoring system is recommended for continuous operation and fully automated operation, as well as for compressor units that do not receive regular attention from specialist personnel. Monitoring tracks the minimum value of stage 1 (intermediate pressure only) and the maximum value of all compressor stages. The compressor unit shuts off if the values monitored fall below or exceed the permissible limit values. The actual value is displayed by the B-CONTROL compressor control unit.

Oil level monitoring
Oil level monitoring

Oil level monitoring
If the oil level reaches the minimum mark, this is indicated on the control display as a warning message. This option is highly recommended for compressor units in continuous operation.

B-APP
B-APP

B-APP
B-APP allows users to remotely control and monitor compressors with the new B-CONTROL MICRO. B-APP also offers additional features such as product-specific news, videos, an integrated dealer search function and calculation tools. Available in the AppStore (iOS) and on GooglePlay (Android). Read more

P 61 filter system
P 61 filter system

P 61 Purification system
The units in the MINI-VERTICUS & VERTICUS series can be supplied with the P 61 purification system integrated as an option. Clean air and gas qualities meeting the requirements of ISO 8573-1 (among others) can be achieved.

P 81 filter system
P 81 filter system

P 81 Purification system
The units in the MINI-VERTICUS & VERTICUS series can be supplied with the P 81 purification system integrated as an option. This system doubles the intervals for changing cartridges compared with the P 61 purification system and meets the requirements of more far-reaching treatment standards.

Particulate filter
Particulate filter

Particulate filter
An integrated particulate filter is offered as an option in conjunction with the P61 and P81 purification systems, to remove particulates safely in compliance with industrial requirements under ISO 8573 class 2.

B-SECURUS filter monitoring
B-SECURUS filter monitoring

B-SECURUS filter monitoring
The B-SECURUS system monitors the saturation of the filter cartridge(s) by measuring the moisture in the molecular sieve. Read more

Intermediate pressure gauges
Intermediate pressure gauges

Intermediate pressure gauges
Analogue pressure gauges mounted on the compressor unit in a suitable location. They make it easy to check, diagnose and maintain the unit.

Intake pressure reduction
Intake pressure reduction

Intake pressure reduction
IIntake pressure reduction ensures that the compressor takes in the gas at the appropriate pressure. The level of intake pressure reduction is adjusted according to prevailing gas pressure and required intake pressure. Integrated safety valves and pressure monitoring effectively ensure that intake pressure does not fall below or above the permissible level.

Exhaust shaft
Exhaust shaft

Exhaust shaft
Two types of exhaust shaft are available for the installation of compressors in containers, housings or service rooms. Read more

Scope of delivery, basic version
Scope of delivery, basic version

Scope of delivery, basic version
Complete compressor unit ready for operation. Read more

MINI-VERTICUS & VERTICUS compressor, 105 – 420 l/min, 90 – 230 bar, helium
Type
designation
Effective
free air delivery ¹
Max. operating
pressure ²
No. of
compr. stages
Speed
approx.
Motor
output
Power
con­sump­tion ¹
Net weight approx.
  l/min m³/h cfm bar psig   rpm kW kW kg lbs
MINI-VERTICUS | 90 – 230 bar, helium
G 120-4-MV 105 6.3 3.7 230 3350 3 900 4 2.7 330 730
G 120-5.5-MV 140 8.4 4.9 230 3350 3 1250 5.5 3.8 340 750
VERTICUS | 90 – 230 bar, helium
G 15.2-15-V 420 25.2 14.8 230 3350 4 1320 15 10.8 425 930
VERTICUS | 90 – 350 bar, helium
G 15.1-7.5-V 240 14,4 8.5 350 5100 4 880 7.5 6.3 400 880
G 15.1-11-V 320 19.2 11.3 350 5100 4 1230 11 9.1 415 910
G 18.1-15-V 420 25.2 14.8 350 5100 5 1490 15 13.3 430 950
MINI-VERTICUS & VERTICUS compressor, 90 – 410 l/min, 90 – 230 bar, argon
Type
designation
Effective
free air delivery ¹
Max. operating
pressure ²
No. of
compr. stages
Speed
approx.
Motor
output
Power
con­sump­tion ¹
Net weight approx.
  l/min m³/h cfm bar psig   rpm kW kW kg lbs
MINI-VERTICUS | 90 – 230 bar, argon
G100-3-MV 90 5.4 3.2 230 3350 3 900 3 3 320 710
G120-4-MV 130 7.8 4.6 230 3350 3 900 4 4 330 730
G120-5.5-MV 180 10.8 6.4 230 3350 3 1250 5.5 5 340 750
VERTICUS | 90 – 230 bar, argon
G15.2-11-V 370 22.0 12.9 230 3350 4 880 11 8.5 415 910
VERTICUS | 90/200 – 350 bar, argon
G15.1-11-V-AR 310 18.6 10.9 350 5100 4 880 11 8.2 415 910
G18.1-11-V 410 24.6 14.5 350 5100 5 1100 11 9.4 420 925

¹ Free air delivery according to ISO 1217, power consumption at maximum final pressure under certain conditions, each valid for helium. Other ambient conditions result in different performance data. Values valid for 50 Hz.
² Max. operating pressure = max. safety valve pressure setting; reduced switch-off pressure.
Values for other noble gases are available on request.