The GIB series: Air-cooled medium pressure booster compressors for the compression of air, nitrogen, helium and argon – for continuous operation in industrial applications

BAUER GIB 23 air-cooled, medium-pressure booster
BAUER GIB 23 air-cooled, medium-pressure booster
BAUER GIB 23 air-cooled, medium-pressure booster
BAUER GIB 23 air-cooled, medium-pressure booster
BAUER GIB 23 air-cooled, medium-pressure booster
BAUER GIB 23 air-cooled, medium-pressure booster
BAUER GIB 23 air-cooled, medium-pressure booster
BAUER GIB 23 air-cooled, medium-pressure booster

Optimum free air delivery rates for your application: For the compression of air, nitrogen, helium and argon

Compressor blocks in the BK 23 – BK 52 series: For uniform absorption of the internal gas forces

Low installation and maintenance costs: An important benefit of air-cooled systems

Powerful air cooling system: For compressor units with drive power ratings up to 110 kW

The air-cooled booster compressors in the GIB series by BAUER KOMPRESSOREN are characterised by their crankcase, which is pressure-resistant up to 16 bar.

A powerful air cooling system with generously dimensioned coolers combined with cylinders with extensive ribbing can be relied upon for best possible cooling of each individual compressor stage.

As cost-effective and durable system solutions for heavy-duty applications, these multi-stage boosters offer a wide and varied range of options: as a booster compressor of air from a compressed air supply system, as a nitrogen compressor of inert gases from generators or storage bundles, or as gas compressors for the compression of methane from pipelines or biogas directly from the treatment system.

In line with your individual needs and industrial requirements, BAUER KOMPRESSOREN can also provide you with tailor-made turnkey system solutions.

All the information you need at your fingertips!

Display B-CONTROL MICRO
Display B-CONTROL MICRO

B-CONTROL MICRO compressor control
The B-CONTROL MICRO is a modern, easy-to-use compressor control with colour display for the control and reliable monitoring of all basic functions. Read more

BK 23 compressor block
BK 23 compressor block

Compressor block
For compressor units with intake pressure, the BK 23 to BK 52 block series feature a pressure-tight crankcase for uniform absorption of the internal gas forces. Read more

Air cooling
Air cooling

Air cooling
Air cooling is part of external cooling. It directly discharges the compressor heat from all locations where heat is critical.
Air-cooled compressors are ideal for mobile or standalone applications. Thanks to the effective dimensioning of air cooling equipment, BAUER KOMPRESSOREN is able to offer air-cooled compressor units with drive power ratings up to 110 kW in proven standard design format.

GIB 23 configuration
GIB 23 configuration

Configuration
The air-cooled series is characterised by its crankcase, which is pressure-resistant up to 16 bar. This makes compression to the required final pressure possible without losses. Read more

Display B-CONTROL II
Display B-CONTROL II

B-CONTROL II
The BAUER B-CONTROL II is the advanced version of the B-CONTROL MICRO basic compressor control. Read More

Special colours
Special colours

Colour range
Customer-specific paint finishes in other colours or special composition paints (conforming to corrosivity category C5M, for example) are available alongside the standard BAUER paint finishes.

Explosion protection design
Explosion protection design

Explosion protection conforming to ATEX guidelines
Compressor units by BAUER KOMPRESSOREN can be supplied with explosion protection and conforming to ATEX directives.

Start-up configuration
Start-up configuration

Start-up configuration
At and above motor power ratings of 75 kW and in conjunction with the B-CONTROL, a soft starter to protect the unit during starting and effectively reduce starting current is used as standard. The technical alternative is soft staring with a frequency inverter. Read more

Monitoring of intermediate pressures and temperatures
Monitoring of intermediate pressures and temperatures

Monitoring of pressure and temperature
This add-on module for the B-CONTROL control monitors the pressures and temperatures of all compressor stages. Read more

Intake pressure reduction
Intake pressure reduction

Intake pressure reduction
Intake pressure reduction ensures that the compressor takes in the gas at the appropriate pressure. Depending on the prevailing gas pressure and the intake pressure required, 1-stage or 2-stage intake pressure reducers are used. Integrated safety valves and pressure monitoring provide an effective means of ensuring that the permissible intake pressure is not exceeded or undershot.

Intake buffer vessel
Intake buffer vessel

Intake buffer vessel
To effectively prevent pulsations in the intake area, an intake buffer vessel is installed between the compressor and the upstream gas supply networks and/or control equipment. Read more

Condensate vessel, 60 litres
Condensate vessel, 60 litres

60-litre condensate vessel
The generous 60 l condensate collection system provides a central collection point for the condensate produced during the compression process inside the compressor. Read more

Condensate vessel (noble gases) with intake buffer vessel on base frame
Condensate vessel (noble gases) with intake buffer vessel on base frame

Condensate vessel (noble gases)
During the compression of helium and argon, the gas released with the condensate is fed into the condensate vessel. Read more

B 2000 storage system
B 2000 storage system

Storage systems
Modular high-pressure storage systems by BAUER KOMPRESSOREN are the ideal way to expand a compressor system. Read more

Scope of delivery, basic version
Scope of delivery, basic version

Scope of delivery, basic version
Complete compressor unit ready for operation. Read more

GIB 23 air-cooled medium-pressure booster; 2200 – 5750 l/min, 25 – 90 bar 4
Type
designation
Effective
free air delivery ¹
Intake
pressure
Shut-down pressure
min. | max. ²
No. of
compr. stages
Speed
approx.
Motor
output
Power
consumption ¹
Net weight approx.
  l/min m³/h cfm bar bar bar   rpm kW kW kg lbs
GIB 23.7-37 2200 132 77 4 25 40 2 1140 37 15 1160 2560
3070 184 108 6 35 60 22
3950 237 139 8 40 80 29
4850 291 171 10 50 80 31
5750 345 203 12 50 80 34

1 Free air delivery according to ISO 1217, power consumption at maximum final pressure under certain conditions. Other ambient conditions result in different performance data. Direct-coupled units: Values valid for 50 Hz.
2 Shut-down pressure (sensor setting).
3 Suitable for helium under certain conditions. Please check with BAUER. Certain restrictions must be considered with regard to input and final pressure.
4 Max. safety valve pressure setting = max. operating pressure. Reduced switch-off pressure.

CORRECTION FACTOR FOR FREE AIR DELIVERY

Helium free air delivery = air free air delivery × 0.8

CORRECTION FACTOR FOR POWER CONSUMPTION

Helium power consumption = air power consumption × 1.06