La nuova sicurezza durante la carica
Scope of delivery for B-SAFE 100 with filling hoses
B-SAFE 100, consisting of safety chamber, explosion-proof doors, with automatic locking for preventing
operating errors, mounted on solid base frame;
in the safety chamber included:
Device for 6 pressure cylinders (optional for 10 cylinders on request)
Optionally with proportional valve (for filling rate 20-50 bar/min – 290-700 psig/min.) or solenoid valve
(filling speed according to delivery from compressor)
Filling device PN 200 resp. 300 bar, consisting of 6 filling hoses with tank connections 5/8“ BSP,
DIN EN 144-2, with automatic vent.
Filling device PN 200/300 bar additionally with pressure reducer, safety valve, pressure sensor and gauge;
numbers of filling connections for pressure range PN 200 and PN 300 bar free selectable, however 6
connections max.
Touch screen for monitoring and controlling of filling process.
Scope of delivery for B-SAFE 100 without filling device
B-SAFE 100, consisting of safety chamber, explosion-proof doors, with automatic locking for preventing
operating errors, mounted on solid base frame; in the safety chamber included:
Device for 6 pressure cylinders
Optionally with proportional valve (for filling rate 20-50 bar/min – 290-700 psig/min.) or solenoid valve (filling speed according to delivery from compressor)
PN 200/300 bar-version with pressure sensor
Touch screen for monitoring and controlling of filling process
Optional are different filling devices available (see below)
Filling panels for B-SAFE 100 without filling device
| Filling Connections |
Safety Valve |
Pressure Reducer |
Order No. |
| 200 bar, 6x, direct |
|
|
075040 |
| 300 bar, 6x, direct |
|
|
073740 |
| 200/300 bar, 6x direct |
 |
 |
075011 |
Filling panels with 6 connections, without B-CONTROL display
Modifications reserved
|