Integrated Design, Quality and Performance
Key Features of BAUER Compressor Technology
1
Intake Filter
Clean, filtered air is essential for proper operation of the compressor. The intake to the compressor is protected by a high performance filter. Additional filtration or treatment of the air may be required for dusty environments or harsh climates.
2
Safety Valves
A safety valve is installed after each stage of compression to ensure safe operation and to protect the compressor from overpressure.
3
Separators
Separators remove oil and water from the compressed air. All separators are made of corrosion resistant materials for long life and to prevent contamination of the compressed air.
4
Crankcase
The crankcase serves as a strong foundation
for the cylinders, sturdy support for the driving
gear and provides a large oil reservoir. The
crankcase is completely sealed against dirt and
moisture for protection of internal components.
BAUER uses a sturdy cast aluminum alloy
crankcase on compressor frames through the
23 series. A rugged cast iron crankcase is used
on the 25 and 28 series compressor frames.
The crankcase is fully encapsulated to prevent
the release of oil laden air to the environment.
5
Lubrication
All BAUER compressors are pressure lubricated
for reliable lubrication of internal components. A
sight glass and replaceable oil filter are standard
on all models.
Drive Gear
All bearing surfaces on the driving gear use long
life roller or needle bearings for reduced friction
and maximum mechanical efficiency. The drive
gear is supported in the crankcase with heavy
duty ball bearings. The dynamically counterbalanced
crankshaft provides smooth, practically
vibration-free operation.
6
Valves
The BAUER design guarantees optimum air
flow and efficiency, thus maximizing valve life.
All valves are readily accessible for inspection and
maintenance. Valve maintenance is inexpensive
and easy to complete.
7
Automatic Condensate Drain (ACD)
The ACD automates the drainage of the interstage
and final separators. This device enhances the
use of the compressor for industrial applications
by eliminating the process of having to drain the
separators manually. The ACD also unloads the
compressor automatically at restarting. Manual
valves are included to override the automatic
operation of the ACD for troubleshooting.
8
Cooling
The BAUER air cooled design is based on more
than 60 years experience. All coolers are located
in the direct blast of the cooling fan(s) for effective
removal of the heat of compression. All cylinders
and cylinder heads have large surfaces and fine
ribbing for maximum heat dissipation. All coolers
are made of corrosion resistant material for long
life and non-contaminating service.
The BAUER design provides discharge air
temperatures of only 20ºF - 40ºF above ambient
temperature depending upon the model.
|