P filter systems for breathing air quality conforming to DIN EN 12021 **
The P-FilterSystem
You need high pressure breathing air? Why does it need purifying? Without purification, air from a piston compressor conforms in no way with the air quality standards required by divers; it is saturated with moisture, contains oil vapours and may taste and smell of impurities.
Therefore, an air processing system is of prime importance.
Without air purification, serious damage to your health and equipment may ensue. Equipment damage includes cylinder corrosion, equipment malfunctions through impurities and iced up, free flowing regulators. Costly repairs and maintenance are some of the consequences. Also hazardous microorganisms may inhabit the cylinder.
The quality of breathing air is largely based on the purification systems and the design of the compressor block. We have 55 years of high pressure experience and know-how - that pays off!
The BAUER P-Filter systems meet and exceed the following international air quality standards:
| Germany: |
DIN EN 12021 and PNEUROP 6611 |
| United Kingdom |
BS 4275 (fire services), BS 4001, part 1.2 (diving) |
| France |
Plongées Profondes Offshore |
| USA |
CGA Grade D+E, Navy Standard Federal Spec. Grade A+B |
| Canada |
CSA |
With the BAUER P-filter system these international standards are met or clearly surpassed.
The Final Separator
is integrated in the VERTICUS units. The oil and water emulsion collects in the bottom of the separator chamber and is drained manually or by means of an automatic condensate drain (optional).
The P-Filter System
The filter system P41 or P61 are part of the standard delivery scope of supply on the VERTICUS models. The filters are carefully selected to match the units' rate of flow and to provide long filter life. Drying agents in the filter cartridge absorbs the residual humidity and water vapours.
Compressed air is treated in three stages:
A - DRYING by adsorption of water vapour particles
B - NEUTRALISATION by adsorption of oil vapour and disturbing odours
C - MICRO FILTERING by binding suspended particles
BAUER's purification cartridges have a filter capacity of 1000 Nm³ (P41) or 1600 Nm³ (P61) at 200 bar (capacity in terms of free air delivery measured at 1 bar absolute, + 20 °C air temperature and + 30 °C final separator temperature).
Standard Scope of Supply
Purchasing BAUER's P-filter system gives you a complete and functional air/gas purification system with:
- Micro separator
- Automatic condensate drain (optional)
- SECURUS monitoring unit (optional)
- Component-tested safety valve
- Corrosion resistant non-return valve
- Filter system with aluminium pressure vessels (TÜV approved)
- Pressure maintaining valve
- All system components are given a special surface treatment for long life corrosion resistance.
Technical Date P-System
| Model |
Nominal pressure 1) |
Flow rate 2) at 200 bar 3000 psig |
Inlet / ambient temp. |
Atmos. dew point |
No. of filters |
Conditionable air
volumes 3) |
Connetion tube Ø |
Dimensions
L × W × H mm / in. |
Weight |
| P40 |
90-420 bar
1300-6000 psig |
450 l/min
15 Scfm |
5-50 °C
40-120°F |
<-70 °C
<-95°F |
1 |
1500 m³
53000 cft |
8 mm |
700×160×700
27 2/3×6 1/4 ×27 2/3 |
40 kg
90 Ibs |
| P60 |
90-420 bar
1300-6000 psig |
600 l/min
20 Scfm |
5-50 °C
40-120°F |
<-70 °C
<-95°F |
1 |
2000 m³
70000 cft |
8 mm |
700×160×900
27 2/3×6 1/4×35 1/2 |
40 kg
100 Ibs |
1) Different pressure range on demand
2) Free air delivery at 1 bar/14,5 psig and 20 °C/68°F
3) Cartridges for removal of oil and moisture at 30 °C/85°F and 200 bar/3000 psig in the final separator
Technical Data of POSEIDON Filtersystems and Filtercartridges
| |
 |
 |
 |
 |
 |
 |
 |
| Filtersystem |
P21 |
P31 |
P41 |
P41 ECOSAFE |
P61 |
P61 ECOSAFE |
P81 ECOSAFE |
| Ref. Filter housing |
W7-7159 |
W7-9873 |
W6-2042 |
W6-1685 |
W6-1082 |
W6-1224 |
W6-1082
W6-1224 |
| Diameter |
95 |
90 |
100 |
100 |
100 |
100 |
100
100 |
| Lenght mm |
265 |
265 |
650 |
650 |
865 |
865 |
865
865 |
| Ref. Filter cartridge |
W5-7679
W5-9183 |
W8-0100
W8-0114 |
W6-2565
W6-7224 |
W6-1686
W6-1687 |
W5-8826
W5-8827 |
W6-0036
W6-0037 |
W5-8826 +
W6-0036 |
| Content of cartridge |
MS/AC/MS
AC/MS/MS/HP |
MS/AC/MS
AC/MS/MS/HP |
MS/AC/MS
AC/MS/MS/HP |
MS/AC/MS
AC/MS/MS/HP |
MS/AC/MS
AC/MS/MS/HP |
MS/AC/MS
AC/MS/MS/HP |
MS/AC/MS
MS/AC/MS |
| Diameter |
43
43 |
70
70 |
70
70 |
70
70 |
70
70 |
70
70 |
70
70 |
| Lenght mm |
200
200 |
245
245 |
490
490 |
505
505 |
710
710 |
720
720 |
710
720 |
| Capacity in m³ * |
160
80 |
610
500 |
1200
1000 |
1200
1000 |
2000
1500 |
2000
1500 |
2000
2000 |
* at 20 °C and at 300 bar pressure
** In combination with Bauer’s AERO-GUARD system, and only when the intake air’s CO2 concentration exceeds the standard threshold.
|